Iai-america IX-NNC8040 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Iai-america IX-NNC8040. IAI America IX-NNC8040 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 90
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Operation Manual Fourth Edition
Horizontal Articulated Robot – IX Series
Tabletop Type, Clean-room Specification
Arm Length 500/600/700/800
IX-NNC50 /60 /70 /80
Zobrazit stránku 0
1 2 3 4 5 6 ... 89 90

Shrnutí obsahu

Strany 1 - Arm Length 500/600/700/800

Operation Manual Fourth Edition Horizontal Articulated Robot – IX Series Tabletop Type, Clean-room SpecificationArm Length 500/600/700/800IX-NNC50

Strany 2

4No.Operation Description Description 4 Installation and Start (4) Safety Measures  When the work is carried out with 2 or more persons, make it cle

Strany 3 - Please Read Before Use

5No.Operation Description Description 6 Trial Operation  When the work is carried out with 2 or more persons, make it clear who is to be the leader

Strany 4 - CE Marking

6No.Operation Description Description 8 Maintenance and Inspection  When the work is carried out with 2 or more persons, make it clear who is to be

Strany 5 - Table of Contents

7Alert Indication The safety precautions are divided into “Danger”, “Warning”, “Caution” and “Notice” according to the warning level, as follows, and

Strany 6

8Caution in Handling1. Make sure to attach the vertical articulated robot properly by following this operation manual.Using the product with the verti

Strany 7 - Safety Guide

91. Names of Robot Parts1 Names of Robot Parts 1.1 Names of Parts I4 joint for user piping, blackUser connectorI6 joint for user piping, redSuction

Strany 8

101. Names of Robot Parts1.2 Labels The following labels are attached on the robot and controller. Be sure to observe the instructions and cautions wr

Strany 9

111. Names of Robot Parts1.3 Label Positions Label Positions on the Robot Robot serial number Prohibition of entry into the operation area View A Warn

Strany 10

122. Transportation and Handling2 Transportation and Handling 2.1 Handling of the Carton Each robot is packed with a controller prior to shipment. Wh

Strany 11

132. Transportation and Handling2.3 Handling of Individual Components The robot and controller are supplied as a set. Your robot cannot be used with

Strany 13 - Alert Indication

142. Transportation and Handling2.5 Transporting the Robot When transporting the robot, affix the arms using the supplied arm fixing plate. Additiona

Strany 14 - Caution in Handling

153. Installation Environment and Storage Environment3 Installation Environment and Storage Environment 3.1 Installation Environment Install the robo

Strany 15 - 1 Names of Robot Parts

163. Installation Environment and Storage Environment3.3 Storage Environment The storage environment conforms to the installation environment. If the

Strany 16 - 1.2 Labels

174. How to Install4.4.1How to InstallShown below is how to install SCARA Robot.Installation Postureż : Available s : Not availableCeiling-MountWall-M

Strany 17 - CE-certified models

184. How to Install4.1 Installing the Robot Install the robot on a level surface. Secure the robot using hex bolts and washers. Type Bolt size Tight

Strany 18 - 2.1 Handling of the Carton

194. How to Install4.3 Connecting the ControllerThe controller connection cables are attached on the robot (standard cable: 5 m, to air-tube joint: 15

Strany 19 - Accessories

204. How to InstallOutput voltage: 24 VDC r 10% Current capacity: 20 to 30 W 24 VDC power supply for brake (provided by user)M cable (outside robot)

Strany 20 - 45 degrees

214. How to Install4.3 Checking after Installation Once the robot has been installed, check the following items: x Visually check the robot, controll

Strany 21 - 3.2 Installation Platform

225. Precautions for Use5 Precautions for Use 5.1 Reference Acceleration/Deceleration Settings Use the robot based on appropriate acceleration/decele

Strany 22 - 3.3 Storage Environment

235. Precautions for Use(2) CP operation (Set using the SEL language commands ACC and DCL.) IX-NNC70/80Reference acceleration/deceleration settin

Strany 23 - How to Install

Please Read Before UseThank you for purchasing an IAI product.This operation manual explains the handling methods, structure and maintenance of this p

Strany 24 - 4.1 Installing the Robot

245. Precautions for Use5.2 Tools The tool mounting part must have sufficient strength and rigidity, along with adequate fastening power to prevent po

Strany 25 - 4.3 Connecting the Controller

255. Precautions for Use5.3 Carrying Load Load capacity Type Rated load capacity Maximum load capacity IX-NNC50/60 2 kg 10 kg IX-NNC70/80 5

Strany 26 - 4. How to Install

265. Precautions for Use5.4 User Wiring and Piping The robot comes with standard cables and tubes that the user can use in a desired wiring/piping co

Strany 27

275. Precautions for UseThe robot comes with a D-sub 25-pin mating plug for the user connector. Solder a user-supplied cable to the D-sub connector (p

Strany 28 - 5 Precautions for Use

285. Precautions for Use5.5 Suction Rate The robot will conform to cleanliness class 10 when air is sucked at a specified rate from the quick suction

Strany 29 - 5. Precautions for Use

296. Inspection/Maintenance6 Inspection/Maintenance6.1 Inspection/MaintenanceYour horizontal articulated robot must be inspected daily and on a regula

Strany 30 - 5.2 Tools

306. Inspection/Maintenance6.1.3 Yearly InspectionCheck the following items on the robot every year.Observe the precautions for work near the robot an

Strany 31 - 5.3 Carrying Load

316. Inspection/Maintenance6.2 How to Replace Bellows 6.2.1 IX-NNC-50/60Preparation The following tools are required when replacing bellows in th

Strany 32 - 5.4 User Wiring and Piping

326. Inspection/Maintenance(3) Remove the stopper at the top and bellows-turning unit at the bottom. (4) Remove the bellows from the robot and separ

Strany 33 - Y-terminal designation

336. Inspection/MaintenanceAssembly (1) Assemble the bellows by following the disassembly procedure in reverse. (2) Install the bellows by aligning

Strany 34 - 5.5 Suction Rate

CE MarkingIf a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME0287) that is provided separately.

Strany 35 - 6 Inspection/Maintenance

346. Inspection/Maintenance6.2.2 IX-NNC-70/80Preparation The following tools are required when replacing bellows in the IX-NNC-70/80:x Hex wre

Strany 36 - 6.1.2 Six-Month Inspection

356. Inspection/Maintenance(3) Remove the bellows-turning unit (one unit each at the top and bottom). (4) Remove affixing plate D from the bellows.

Strany 37 - 6.2 How to Replace Bellows

366. Inspection/MaintenanceAssembly (1) Assemble the bellows by following the disassembly procedure in reverse. (2) Install the bellows by aligning

Strany 38 - 6. Inspection/Maintenance

376. Inspection/Maintenance6.3 How to Check/Adjust Belt Tension 6.3.1 Preparation The following tools are required when checking/adjusting belt tensi

Strany 39

386. Inspection/Maintenance6.3.2 Removing the Cover (1) With arms 1 and 2 extended as illustrated below, press the brake-release switch [1] to relea

Strany 40 - 6.2.2 IX-NNC-70/80

396. Inspection/Maintenance6.3.3 Checking the Belt Tension Bottom view Timing belt for vertical axis Timing belt for rotational axis Top view 6.3.4 C

Strany 41

406. Inspection/Maintenance6.3.5 Checking the Belt Tension for the Rotational Axis (1) Remove one setscrew provided on a side face of arm 2. Remove

Strany 42

416. Inspection/Maintenance6.3.6 Adjusting the Belt Tension for the Vertical Axis (1) Loosen the four M5 nuts [4] slightly, making sure the fastened

Strany 43 - 6.3.1 Preparation

426. Inspection/Maintenance6.3.8 Installing the Cover (1) Place the cover on the robot and connect the connectors, cables and air tubes installed as

Strany 44 - 6.3.2 Removing the Cover

436. Inspection/Maintenance[3] 4 - M3 x 12M cable Installation position of M connector Installation position of U connectorsU cables Be careful

Strany 45 - Top view

Table of Contents Safety Guide ······················································································································1

Strany 46

446. Inspection/Maintenance6.4 Battery Replacement 6.4.1 Preparation The following items are required when replacing the batteries: x Phillips screwdr

Strany 47

456. Inspection/Maintenance6.4.2 Battery Replacement Procedure (1) Remove the countersunk head screws [1] (six pieces) and detach the cover (base).

Strany 48 - 6.3.8 Installing the Cover

466. Inspection/Maintenance(5) Affix the cover (base) using the countersunk head screws [1] (six pieces) (tightening torque: 0.74 Nm). [1] 6 - M3 x

Strany 49

476. Inspection/Maintenance6.5 Absolute Reset Procedure 6.5.1 Preparation for Absolute Reset The following jig is required when performing an absolut

Strany 50 - 6.4 Battery Replacement

486. Inspection/Maintenance6.5.2 Starting the Absolute Reset Menu (1) Open the absolute reset window from the PC software. (2) The absolute reset w

Strany 51 - Battery holder

496. Inspection/Maintenance6.5.3 Absolute Reset Procedure for Arm 1 or 2 (1) Click the “Encoder Rotation Data Reset1” button. (2) Click the “Reset

Strany 52

506. Inspection/Maintenance(3) Click the “Servo ON” button. (4) Jog the arm to near the reference position (see reference position drawing in step 7

Strany 53 - 6.5 Absolute Reset Procedure

516. Inspection/Maintenance(6) Press the emergency-stop switch. (7) Set an adjustment jig (pin) in arm 1 or 2 to fix the arm at the reference positi

Strany 54

526. Inspection/Maintenance(8) Click the “OK” button. (9) Click the “Encoder Rotation Data Reset2” button.

Strany 55

536. Inspection/Maintenance(10) Remove the adjustment jig. x If you are working on arm 1, install the cover and secure it with the setscrews (not req

Strany 56 - “Jog end” button

8. Warranty ·················································································································· 798.1 Warranty Period ·

Strany 57 - Reference position drawing

546. Inspection/Maintenance6.5.4 Absolute Reset Procedure for the Rotational Axis + Vertical Axis (1) Click “Encoder Rotation Data Reset1” button. (

Strany 58 - (8) Click the “OK” button

556. Inspection/Maintenance(3) Click the “Servo ON” button. (4) Click the “Temp. Standard posture standby” button. x The vertical axis returns to it

Strany 59

566. Inspection/Maintenance(6) Click the “Servo-OFF” button. (7) Press the emergency-stop switch. (8) Affix the rotational axis at the reference po

Strany 60

576. Inspection/Maintenance(9) Click the “OK” button. (10) Click the “Encoder Rotation Data Reset2” button.

Strany 61

586. Inspection/Maintenance(11) Click the “Home pos. automatic update” button. (12) Remove the adjustment jig. (13) Release the emergency-stop swit

Strany 62

596. Inspection/Maintenance(15) Click the “Servo ON” button. (16) Click the “Standard posture standby” button. x The vertical axis returns to its ho

Strany 63 - (9) Click the “OK” button

606. Inspection/Maintenance(18) Click the “Encoder Rotation Data Reset3” button. (19) Click the “Home pos. automatic update” button, and then click

Strany 64 - (14) Click the “OK” button

616. Inspection/Maintenance6.5.5 Writing the Flash ROM (1) Following an absolute reset of the rotational axis and vertical axis, the following scree

Strany 65

626. Inspection/Maintenance6.5.6 Resetting the Controller (1) Select “Software Reset” from the Controller menu on the tool bar. (2) Click the “Yes”

Strany 66

637. Specifi cations7 Specifications 7.1 Specification Table IX-NNC50 (Arm Length 500, Clean-room Specification) Item Specifications Type IX-NNC50

Strany 67 - 6.5.5 Writing the Flash ROM

1Safety Guide“Safety Guide” has been written to use the machine safely and so prevent personal injury or property damage beforehand. Make sure to read

Strany 68

647. Specifi cationsItem SpecificationsTemperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)Altitude m 1,000 or lessNoise dB 73Cleanli

Strany 69 - 7 Specifications

657. Specifi cationsIX-NNC60 (Arm Length 600, Clean-room Specification) Item Specifications Type IX-NNC60-L-T1 Degree of freedom Four degrees o

Strany 70 - 7. Specifi cations

667. Specifi cationsItem SpecificationsTemperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)Altitude m 1,000 or lessNoise dB 73Robot w

Strany 71

677. Specifi cationsIX-NNC70 (Arm Length 700, Clean-room Specification) Item Specifications Type IX-NNC70-L-T1 Cleanliness class (*10)Class 10 (

Strany 72

687. Specifi cationsItem SpecificationsTemperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)Altitude m 1,000 or lessNoise dB 74Robot w

Strany 73

697. Specifi cationsIX-NNC80 (Arm Length 800, Clean-room Specification) Item Specifications Type IX-NNC80-L-T1 Cleanliness class (*10)Class 10 (

Strany 74

707. Specifi cationsItem SpecificationsAmbient temperature/humidityTemperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)Operatingenvir

Strany 75

717. Specifi cations7.2 External Dimensions IX-NNC504 - I11 hole I24 counterbore, depth 5 5 (Mechanical end) 2-M4 depth 8 (*1) Air joint (o

Strany 76

727. Specifi cationsIX-NNC604 - I11 hole I24 counterbore, depth 5 5 (Mechanical end) 2-M4 (*1) Air joint (opposite side)Applicable tube: Outer di

Strany 77 - 7.2 External Dimensions

737. Specifi cationsIX-NNC70Applicable tube: Outer diameter I12(inner diameter I8) Air joint (*4) Arm 2 stopper4 - I14 hole I30 counterbore, depth

Strany 78 - IX-NNC60

2No.Operation Description Description 2 Transportation  When carrying a heavy object, do the work with two or more persons or utilize equipment su

Strany 79 - IX-NNC70

747. Specifi cationsIX-NNC80Applicable tube: Outer diameter I12(inner diameter I8) Air joint (*4) Arm 2 stopper4 - I14 hole I30 counterbore, depth

Strany 80 - IX-NNC80

757. Specifi cations7.3 Robot Operation Area IX-NNC50(Operation prohibited area) Stopper position range Movement range IX-NNC60(Operation prohibite

Strany 81 - 7.3 Robot Operation Area

767. Specifi cationsIX-NNC70(Operation prohibited area) Stopper position range Movement range IX-NNC80(Operation prohibited area) Stopper position

Strany 82

777. Specifi cations7.4 Wiring Diagram Wiring/Piping Diagram (Arm Length: 500/600) Controller Inside base Inside arm 2Cable fix cap (Capcon) Servo mot

Strany 83 - 7.4 Wiring Diagram

787. Specifi cations7.5 230V Circuit Components IX-NNC50/60No. Code name Model Manufacturer Remarks1 Axis 1 servo motor TS4609 N2027 E200AC s

Strany 84

798. Warranty8. Warranty 8.1 Warranty Period One of the following periods, whichever is shorter: y 18 months after shipment from IAI y 12 months

Strany 85 - 8. Warranty

808. Warranty8.5 Conditions of Conformance with Applicable Standards/Regulations, Etc., and Applications(1) If our product is combined with another

Strany 86 - Applications

81Change HistoryChange History Revision Date Description of RevisionA page for CE Marking addedIntroduction, Safety Symbols and Safety Precautions are

Strany 89

3No.Operation Description Description (2) Cable Wiring  Use our company’s genuine cables for connecting between the actuator and controller, and for

Strany 90 - 12.08.000

Manual No.: ME3628-4A (August 2012)The information contained in this document is subject to change without notice for purposes of product improvement.

Komentáře k této Příručce

Žádné komentáře