4.5.3 Setting the IP Address
Set parameter No. 140, “IPAD: IP address.”
[Refer to 4.9, “EtherNet/IP Parameters.”]
Settable Range:0.0.0.0 to 255.255.255.255 (It is set to “192.168.0.1” when the machine is delivered from
the factory.)
(Note 1) Exercise caution to avoid IP address duplication.
For details, refer to the operation manuals of the master unit and PLC in which in the master unit
is installed.
4.5.4 Setting the Subnet Mask
Set parameter No. 141, “SNMK: Subnet mask.”
Set the same value you have set in the master unit and other slaves (on the same network).
[Refer to 4.9, “EtherNet/IP Parameters.”]
Settable range: 0.0.0.0 to 255.255.255.255 (The factory setting is 255.255.255.0.)
4.5.5 Setting the Default Gateway
If necessary, set parameter No. 142, “DFGW: Default gateway.”
[Refer to 4.9, “EtherNet/IP Parameters.”]
Settable range: 0.0.0.0 to 255.255.255.255 (The factory setting is 192.168.0.0.)
(Note) After the parameter setting, turn on the power to the controller again and return the mode toggle switch
on the front of the controller to “AUTO” side.
When the switch is set to “MANU”, the operation using PLC is not available.