4. PCON-CA/CFA
CC-Link
87
4.3 CC-Link Interface
(1) Names of Each Section
The names of each section related to CC-Link are described as follows.
(2) Status LED Indication
The board operation status and network condition are obtained with the two LEDs located in the front of
the controller.
: Illuminating, : OFF, : Flashing
LED Color Indication Status Indication Description (Meaning)
x An error occurs.
(CRC Error/Station No. (parameters) Setting Error/Baud Rate
Setting (parameters) Error)
x Period between power up or software reset and the CC-Link
initialization completion
x Under Normal Communication
ERR OR
(0.4sec)
x Station No. setting or communication speed setting is changed
during the communication.
x Communicating normally
RUN GN
x Not communicating
SV/ALM Status Indicator LED
FG
SLD
DG
DB
DA
ERR
RUN
CC-Link Communication Connector
Status LED
PCB side : MSTBA2.5/5-G-5.08AU
(PHOENIX CONTACT)
Cable side : SMSTB2.5/5-ST-5.08AU
(PHOENIX CONTACT)