347
Appendix
INTELLIGENT ACTUATOR
I/O Parameters
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
150 IAI protocol B/TCP: IP
address of connection
destination (MANU
mode) (MH)
168 0 ~ 255
151 IAI protocol B/TCP: IP
address of connection
destination (MANU
mode) (ML)
0 0 ~ 255
152 IAI protocol B/TCP: IP
address of connection
destination (MANU
mode) (L)
100 0 ~ 254
* Setting of 0 and 255 is prohibited.
153 IAI protocol B/TCP: Port
number of connection
destination (MANU
mode)
64611 0 ~ 65535
* 0 can be set, if server.
0 = Port number of connection destination
ignored
(Only IP address is checked)
* 0 cannot be set, if client.
154 IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(H)
192 0 ~ 255
* Setting of 0 and 127 is prohibited.
155 IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(MH)
168 0 ~ 255
156 IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(ML)
0 0 ~ 255
157 IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(L)
100 0 ~ 254
* Setting of 0 and 255 is prohibited.
158 IAI protocol B/TCP: Port
number of connection
destination (AUTO mode)
64611 0 ~ 65535
* 0 can be set, if server.
0 = Port number of connection destination
ignored
(Only IP address is checked)
* 0 cannot be set, if client.
159 IAI protocol B/TCP: Own
port number (AUTO
mode)
64516 1025 ~ 65535
* Important: Be sure to set a different number
for each own port number. (Duplication is
permitted only for own port numbers under
IAI protocol B/TCP in the MANU/AUTO
modes.)
0
0
160
~
169
(For network extention) 0
170
~
200
(For extention) 0
~
~
PC: PC software
TP: Teaching pendant