(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
B00 SCHA setting error The setting of SCHA command is invalid.
B01 TPCD setting error The setting of TPCD command is invalid.
B02 SLEN setting error The setting of SLEN command is invalid.
B03 Home-return method error The setting of “Axis-specific parameter No. 10, Home-return method” is invalid.
(Not incremental encoder AND current position 0 home is specified, etc.)
B04 1-shot-pulse output excessive simultaneous use error The number of BTPN and BTPF timers operating in one program simultaneously
exceeds the upper limit (16).
B05 Estimate-stroke over error at home return The operation at home return exceeded the estimate stroke. The home sensor
or creep sensor may be faulty, among other reasons.
B06 Expanded-SIO in-use error An attempt was made to open a channel already opened by other task.
B07 Expanded-SIO unopen error An attempt was made to use a channel not opened by own task.
B08 Expanded-SIO duplicate WRIT execution error WRIT commands were executed simultaneously by multiple tasks for the same
channel.
B09 Expanded-SIO RS485 WRIT/READ simultaneous execution error WRIT and READ commands were executed simultaneously in the RS485 mode.
B0A Expanded-SIO unassigned-channel use error An attempt was made to use a channel not assigned properly. Check I/O
parameter Nos. 100 to 111 and the statuses of I/O slots.
B10 Phase-Z search timeout error Phase Z cannot be detected. Check for operation restriction, wiring, encoder,
motor, etc.
B11 Home-sensor pull-out timeout error Pull-out from the home sensor cannot be confirmed. Check for operation
restriction, wiring, motor, home sensor, etc.
B12 Storage variable number error for SEL command return code Invalid number of the variable that stores the code returned by the SEL command
B13 Backup SRAM data checksum error The backup SRAM data has been destroyed. Check the battery.
B14 Flash-ROM, 8-Mbit version unsupported function error An attempt was made to use a function not supported in the flash-ROM, 8-Mbit
board environment.
(HT connection specification, etc.)
B15 Input-port debug filter type error The setting of input-port debug filter type is invalid.
B16 SEL operand specification error The operand specification of SEL command is invalid.
B17 Parameter register busy error at issuance of slave command The driver special command ACK generated a timeout at issuance of a slave
command.
B18 Device number error The device number is invalid.
B19 Unit type error The unit type is invalid
B1A Absolute reset specification error The specification for absolute reset using an optional function, etc., is invalid.
(Two or more axes are specified simultaneously, non-absolute-encoder axis is
specified, etc.)
B1B Ethernet “opening socket without closing” error An attempt was made to open a socket again without closing it first.
B1C Ethernet “other task in use” error An attempt was made to open again a channel which is already open in other
task.
B1D Ethernet non-open error An attempt was made to use a channel not yet opened in the applicable task.
B1E Ethernet multiple WRIT execution error WRIT commands were executed simultaneously to the same channel in multiple