Appendix
INTELLIGENT ACTUATOR
380
Error List
(MAIN application) (In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
207
Update file name error (IAI protocol) The name of the selected update program file is invalid in the update mode. Select
the correct file and repeat the update procedure from the beginning.
20E
Motorola S byte count error The update program file is invalid. Check the file.
20F
Update target specification error (Application reception) An update target specification command was application reception system. To
perform an update, restart the controller and repeat the update procedure from the
beginning.
630
Update system code error (Application detection) The update system code is invalid.
631
Update unit code error (Application detection) The update unit code is invalid.
632
Update device number error (Application detection) The update device number is invalid.
801 SCIF overrun status (IAI protocol reception) Communication failure. Check for noise, connected equipment and communication
setting.
802 SCIF receive ER status (IAI protocol reception) Communication failure. Check for noise, shorted/disconnected communication cable,
connected equipment and communication setting. This error will also occur when
establishing communication with the PC/TP wrongly connected to SIO-CH1 being
opened to the user.
803 Receive timeout status (IAI protocol reception) The transfer interval after the first received byte is too long. Possible causes include
disconnected communication cable and error in the connected equipment.
804 SCIF overrun status (SEL reception) Communication failure. Check for noise, connected equipment and communication
setting.
805 SCIF receive ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication cable,
connected equipment and communication setting.
806 SCIF receive ER status due to other factor (SEL reception)
Communication failure. Take the same action specified for error No. 804 or 805.
807 Drive-source cutoff relay ER status The motor drive-power supply status remains ON although the drive source has been
cut off. Or, the drive-source cutoff relay contacts may have been fused.
808 Power OFF status during slave parameter write The power was turned off while writing slave parameters. (This error can be detected
only when a backup battery is used.)
809 Power OFF status during data write to flash ROM The power was turned off while writing data to the flash ROM. (This error can be
detected only when a backup battery is used.)
80A Expanded-SIO overrun status (SEL reception) Communication failure. Check for noise, connected equipment and communication
setting.
80B Expanded-SIO parity ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication cable,
connected equipment and communication setting.
80C Expanded SIO framing ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication cable,
connected equipment and communication setting.
80D Expanded-SIO receive ER status due to other factor (SEL reception) Communication failure. Take the same action specified for error No. 80A, 80B or
80C.
80E Expanded-SIO receive buffer overflow status (SEL reception)
The receive buffer overflowed. Excessive data was received from outside.
80F
Ethernet control status 1
Ethernet control information (for analysis)
810
Ethernet control status 2
Ethernet control information (for analysis)
811
Maintenance information 1
Maintenance information (for analysis)
812
Maintenance information 2
Maintenance information (for analysis)