INTELLIGENT ACTUATOR
Part 1 Installation
Chapter 3 Installation Environment and Noise Measures
1. Installation Environment
As for the use environment, this product can be used in an environment of pollution degree 2
*1
or
equivalent.
*1 Pollution degree 2: Normally only non-conductive pollutants exist, which are expected to be
temporarily conductive due to condensation. (IEC60664-1)
(1) When installing and wiring the controller, do not block the ventilation holes provided for cooling.
(Insufficient ventilation will not only prevent the product from functioning fully, but it may also result in
failure.)
(2) Prevent foreign matter from entering the controller through the ventilation holes. Since the controller is
not designed as dustproof or waterproof (oilproof), avoid using it in a dusty place or place subject to
oil mist or splashed cutting fluid.
(3) Do not expose the controller to direct sunlight or radiant heat from a high heat source such as a heat-
treating furnace.
(4) Use the controller in a non-condensing environment free from corrosive or inflammable gases.
(5) Use the controller in an environment where it will not receive external vibration or impact.
(6) Prevent electrical noise from entering the controller or its cables.
Environmental Condition of Controller
noitacificepS metI
Surrounding air temperature range
0?C ~ 40?C
Forced air-cooling
24 VDC fan x 5 (2-axis type)
24 VDC fan x 6 (4-axis type)
Surrounding humidity range 30% ~ 85%
Storage temperature range
-10?C ~ 65?C
Dust protection structure IP20
Power-source voltage 230 VAC, single-phase
Operating power-source voltage
? 10%
Rated operating power-source
frequency
50 Hz/60 Hz
2. Heat Radiation and Installation
Design the control panel size, controller layout and cooling method so that the surrounding air
temperature around the controller will be kept at or below 40°C.
Install the controller vertically on a wall, as illustrated below. The controller will be cooled by forced
ventilation (exhaust air will be discharged from the top). Be sure to install the controller in the
aforementioned direction and provide a minimum clearance of 150 mm above and 150 mm below the
controller.
If multiple controllers are to be installed side by side, providing additional suction fans on top of the
controllers will help maintain a uniform surrounding air temperature.
Provide a minimum clearance of 150 mm between the front side of the controller and a wall
(enclosure).