37
INTELLIGENT ACTUATOR
Part 1 Installation
4) Internal Circuit Selector Terminals
Silkscreen printed
name
TP (ANSI/IAI) SELECT
Description
This connector terminal block is used to select internal circuits of
the relay box.
The shorting connections between the connector terminals are
changed in accordance with the teaching pendant used.
Connector MC1.5/6-ST-3.5 (Phoenix Contact)
Terminal Numbers and Descriptions of Internal Circuit Selector Terminals
Terminal number Description
1
Shorted to pin 2 when the ANSI-compatible teaching pendant SEL-
TD and IA-T-XA are used.
(Opened when the teaching pendant SEL-T and IA-T-XD are
used.)
2
Shorted to pin 1 when the ANSI-compatible teaching pendant SEL-
TD and IA-T-XA are used.
(Opened when the teaching pendant SEL-T and IA-T-XD are
used.)
3
Shorted to pin 4 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD is
used.)
4
Shorted to pin 3 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)
5
Shorted to pin 6 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)
6
Shorted to pin 5 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)
6 1 6 1
When the teaching pendant
SEL-T and IA-T-XD are
used
When the ANSI-compatible teaching
pendant SEL-TD and IA-T-XA are
used
When this wiring pattern is
used, use a dummy plug
for IAI’s teaching pendant.
When this wiring pattern is
used, use a dummy plug
for ANSI-compliant
teaching pendant.