(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
C24 Operand type error Program step error. The operand data type is invalid.
C25 Actuator control declaration error The setting of actuator control declaration command is invalid.
C26 Timer setting-range over error The timer setting is invalid.
C27 Timeout setting-range over error during wait The timeout setting is invalid.
C28 Tick count setting-range error The Tick count setting is invalid.
C29 DIV command divisor 0 error “0” was specified as the divisor in the DIV command.
C2A SQR command range error The operand value in the SQR command is invalid. Input a value larger
than “0” as data in a SQR command.
C2B BCD display digit range error The specified number of BCD display digits is invalid. Specify a value
between 1 and 8.
C2C Program number error A program number other than 1 to 64 was specified.
C2D Step number error The step number is invalid.
C2E Blank step shortage error There are not enough blank steps to save step data. Provide enough
blank steps needed to save step data.
C2F Axis number error The axis number is invalid.
C30 Axis pattern error The axis pattern is invalid.
C32 Operating-axis addition error during command execution An operating axis for point data was added during continuous point
movement or push-motion movement calculation.
C33 Base axis number error The base axis number is invalid.
C34 Zone number error The zone number is invalid.
C35 Point number error The point number is invalid.
C36 I/O port/flag number error The I/O port/flag number is invalid.
C37 Flag number error The flag number is invalid.
C38 Tag number error The tag number is invalid.
C39 Subroutine number error The subroutine number is invalid.
C3A User-opened communication channel number error The user-opened communication channel number is invalid.
C3B Parameter number error The parameter number is invalid.
C3C Variable number error The variable number is invalid.
C3D String number error The string number is invalid.
C3E String-variable data count specification error The specified number of string variables exceeds the area, etc.
C40 String-variable delimiter non-detection error Delimiter cannot be detected in the string variable.
C41 String-variable copy size over error The copy size of string variable is too large.
C42 Character count non-detection error during string processing The character-string length is not defined in string processing. Execute